AFM Scanner Calibration
Precision calibration of atomic force microscopy scanners and piezoelectric sensors to ensure accurate XYZ linearity, reduce hysteresis, and maintain reliable topographic measurements across varied sample surfaces.
Onsite calibration for AFM and STM platforms. Scanner calibration, optical path alignment and hardware verification are carried out in your own laboratory, so drift and vibration are assessed in the environment the instrument actually runs in. Height and lateral accuracy are referenced to step-height and grating standards.

We offer specialized onsite calibration, diagnostic maintenance, and scanner alignment services to keep your laboratory microscopes operating with nanoscale precision.
Precision calibration of atomic force microscopy scanners and piezoelectric sensors to ensure accurate XYZ linearity, reduce hysteresis, and maintain reliable topographic measurements across varied sample surfaces.
Complete onsite calibration of scanning tunneling microscopy preamplifiers, bias electronics, and feedback control loops to secure atomic-level resolution and sensitive current measurement in advanced experiments.
Diagnostic testing, mechanical stage alignment, replacement part checks and system recalibration, carried out at your site to limit instrument downtime.

Our engineers evaluate your AFM or STM instrumentation hardware, thoroughly examining physical connections, scanner integrity, and control electronics to identify any baseline performance drift or operational issues before beginning system adjustments.
Decades of dedicated nanoscale instrumentation expertise ensuring uncompromising precision for your research laboratory.
Founded and led by original AFM engineers possessing deep institutional knowledge of scanning probe systems.
Rigorous calibration protocols ensure your microscopy platforms deliver dependable, high-resolution atomic imaging and surface measurements.
Replacement parts, custom configurations and accessories for legacy Agilent 5500, 4500, 5100 and 5420 platforms.
Prompt service coordination through ZoomAFM diagnostics and experienced technical support to minimize laboratory research downtime.
Specialized AFM and STM engineers supporting nanoscale research worldwide.
Leader / Co-Founder (Revival Team)
Dr. Song Xu is a founding leader of the revived Molecular Imaging, having been instrumental in reuniting former employees after Keysight Technologies exited the AFM market in 2018. With deep institutional knowledge of Molecular Imaging's original technology and mission, he guides the company's strategic direction and technical development. Dr. Xu's expertise spans atomic force microscopy and nanoscale imaging systems, ensuring the company continues to deliver modular, precise, and user-friendly instrumentation. He is deeply committed to supporting researchers in nanotechnology, life sciences, and materials science, and works to ensure every customer receives reliable systems backed by strong technical support. Dr. Xu's leadership reflects a passion for continuing Molecular Imaging's legacy of innovation and collaboration for the global scientific research community.

Team Member (Revival Team)
Steve Raba is a former Molecular Imaging professional who returned to help revive the company after Keysight Technologies' exit from the AFM market in 2018. His background spans application support, production, engineering, and R&D, giving him a well-rounded perspective on delivering high-quality AFM and STM instrumentation. Steve plays a key role in ensuring Molecular Imaging's systems meet the exacting standards required by researchers in nanotechnology, life sciences, and materials science. His hands-on experience with the company's original technology allows him to contribute valuable insight into product development and customer support. Steve is dedicated to helping the global research community achieve precise, reliable results through Molecular Imaging's advanced instrumentation and dependable service.

Team Member (Revival Team)
John Alexander is a former Molecular Imaging professional who rejoined the team to help restore the company following Keysight Technologies' departure from the AFM market in 2018. His experience covers application support, production, engineering, and R&D, providing valuable expertise across the full lifecycle of AFM and STM system development. John's contributions help ensure Molecular Imaging's instruments remain modular, flexible, and dependable for researchers across nanotechnology, life sciences, and materials science fields. He is committed to maintaining the high standards of precision and usability that originally defined the Molecular Imaging brand. John's dedication to quality and customer satisfaction supports the company's mission of empowering the global research community with advanced nanoscale imaging solutions.

Team Member (Revival Team)
Klaus Vicaro is a former Molecular Imaging professional who joined the effort to revive the company after Keysight Technologies exited the AFM market in 2018. He brings valuable experience in application support, production, engineering, and R&D to the organization's renewed mission. Klaus plays an important role in supporting the development and refinement of Molecular Imaging's AFM and STM product lines, helping ensure they meet the needs of researchers in nanotechnology, life sciences, and materials science. His technical background and familiarity with the company's original systems contribute to maintaining the precision and reliability customers expect. Klaus is committed to helping Molecular Imaging continue its legacy of innovation and dependable service for the global scientific community.

Team Member (Revival Team)
John Ris is a former Molecular Imaging professional who joined the revival team following Keysight Technologies' 2018 exit from the AFM market. His expertise spans application support, production, engineering, and R&D, contributing to the company's ability to deliver advanced, user-friendly AFM and STM systems. John plays a vital role in supporting the technical and operational aspects of Molecular Imaging's product offerings, helping serve researchers across nanotechnology, life sciences, and materials science. His familiarity with the company's original technology and commitment to quality help maintain the precision and reliability that define Molecular Imaging's instruments. John remains dedicated to advancing the company's mission of innovation and collaboration for the global research community.

Academic Advisor
Dr. Stuart Lindsay serves as academic advisor to Molecular Imaging, bringing extensive scientific expertise and vision to the company's renewed mission. His guidance supports the organization's commitment to advancing atomic force microscopy technology for researchers in nanotechnology, life sciences, and materials science. Dr. Lindsay's academic background provides valuable insight that helps shape Molecular Imaging's product development and research applications, ensuring the company remains at the forefront of nanoscale imaging innovation. His involvement reflects the collaborative spirit that has defined Molecular Imaging since its original founding. Dr. Lindsay is dedicated to helping the company deliver unparalleled precision, versatility, and control in AFM/SPM systems, supporting the global research community in their pursuit of scientific discovery.
Our onsite calibration service includes a full evaluation of microscope hardware, optical alignment, and detector responsiveness. Technicians verify piezoelectric scanner sensitivity along lateral and vertical axes using precision reference standards. We also inspect electronic feedback loops, perform diagnostic tests to identify baseline drift, and ensure the entire instrument operates in accordance with manufacturer specifications for dependable nanoscale measurement.
Speak with our technical specialists to schedule your laboratory calibration service.
Reorganized by former Molecular Imaging staff after Keysight Technologies withdrew from the AFM market in 2018.
Specialized repair capabilities on most Molecular Imaging, Agilent and Keysight-branded AFM products.
Send the instrument model, site location and the measurement problem you are seeing, and we will confirm what the onsite visit needs to cover and which parts to bring.
For immediate assistance, feel free to give us a direct call at 1-888-644-0389. You can also send us a quick email at songxu@nanocuetech.com.
For immediate assistance, feel free to give us a direct call at 1-888-644-0389. You can also send us a quick email at songxu@nanocuetech.com.